Conference Hall Acoustics
- ISO 354
- Acoustic testing standard
- RT60
- Echo time measured in the project
- Technical documents
- Acoustic and fire reports
- 117
- Colour options
Why Are Conference Hall Acoustics So Important?
PET felt wall and ceiling systems are manufactured to suit conference hall projects. Models, dimensions, colours and mounting details are defined using the architectural drawings.
In large halls, sound is reflected many times from the back walls and high ceilings. When the reverberation time increases, the speaker's words become confused and intelligibility is practically lost for the back rows.
The source of the problem is hard surfaces, large internal volume and placement of the sound system. Target reverberation time; It should be determined by the acoustic consultant according to the hall volume, usage type and relevant project standard.
Wall and ceiling solutions control reflected sound energy. The layout decision should be based on hall geometry and measurement results, not just the product coefficient.
Hearability and Aesthetics Together
Determine the location of absorbent surfaces in the conference hall together with the stage, seating arrangement and sound system. The back wall and high ceiling are surfaces where late reflections should be examined.
Models, dimensions and mounting options are defined to suit the geometry and use of the space.
Conference Acoustics Planning: What is Needed in Which Area?
The ceiling structure, stage width and seating arrangement of the hall create different acoustic dynamics. An incorrectly calculated product placement will not solve the problem.
- 01
Main Hall and Ceiling
Ceiling surfaces play an important role in sound propagation in conference halls. Baffles and ceiling islands are positioned in coordination with room geometry, seating layout and existing building services.
- 02
Foyer and Reception
High ceilings and hard floors add a natural echo effect to the foyer. In these areas where hundreds of people talk at the same time between events, it is necessary to cut the noise and balance the crowd noise.
- 03
Workshop and Seminar Rooms
Echo control should also be provided in the smaller workshop and seminar rooms around the large hall. Sound transmission between adjacent rooms is handled by sound insulation of partition walls, doors, ceiling gaps and joint details. In-room absorber panels are used to control reflections.
- 04
Behind the Scenes
The surfaces around the stage are evaluated together with the microphone and speaker positions. Absorbent surfaces can be used in appropriate areas; Feedback control also requires the placement and settings of the audio system.
Conference Hall Products: Wall Panels
Walls, which make up the majority of the surface area, form the basis of the acoustic project. Model, thickness and application area; It is selected by evaluating the acoustic targets of the space and the frequency-dependent absorption data of the product.
Ceiling Systems and screens
Ceiling baffles and wall panels provide absorption on different surfaces. The layout is determined by the geometry of the hall and the coverage area of the sound system.
Technical Specifications
Acoustic, fire and chemical test results of PET felt products are evaluated on a sample basis. After selecting the thickness, colour/series and assembly condition, the relevant report scope is matched in the project file.
- Composition
- 100% polyester PET felt · 60% recycled content
- Thickness and Weight
-
- 9 mm (±0.5 mm) · 1,600 g/m² (±10%)
- 12 mm (±0.5 mm) · 2,400 g/m² (±10%)
- 18 mm · 3.500 g/m²
- 20 mm (±1 mm) · 3,000 g/m² (±10%)
- 24 mm (±0.5 mm) · 3,700 g/m² (±10%)
- Lamination
-
- Dual colour · 9 mm (±0.5 mm): 1.600 + 200 + 200 g/m² (±10%)
- Dual colour · 12 mm (±0.5 mm): 2.400 + 200 + 200 g/m² (±10%)
- Different colours can be used on the front and back surfaces or layers.
- Acoustic
-
- 12 mm 2,400 g/m² without air gap: NRC 0.45 / αw 0.30
- 12 mm 2,400 g/m² 200 mm air gap: NRC 0.85 / αw 0.75
- 18 mm 3,500 g/m² 200 mm air gap: NRC 0.85 / αw 0.80
- 24 mm 3,700 g/m² 200 mm air gap: NRC 0.90 / αw 0.80
- Fire Tests
-
- EN 13501-1 / B-s1,d0 · AK 1100 black, 9 mm, 1,100 g/m²; mechanical fixation, test specimen without air gap
- ASTM E84 / Class A · Grey Arketa sample, 9 mm, 177.7 kg/m³ (FTST241350)
- Material Tests
-
- The OEKO-TEX certificate and its scope are available on request.
- Cleaning
- Clean gently with a soft, damp cloth.
Colour Chart
In the colour chart, there is a 117 option in the 5 series. Check the body and surface options on your product's colour chart.
Mono
Single layer, solid solid colour throughout the panel.
13 colours-
M-01 Mono White -
M-02 Mono Light Grey -
M-03 Mono Grey -
M-04 Mono Dark Grey -
M-05 Mono Black -
M-06 Mono Camel -
M-07 Mono Caramel -
M-08 Mono Orange -
M-09 Mono Red -
M-10 Mono Pine Green -
M-11 Mono Ocean Blue -
M-12 Mono Ash Grey -
M-13 Mono Olive
Mono Heathered
A marled finish version of Mono.
10 colours-
MH-01 Mono Heathered Light Grey -
MH-02 Mono Heathered Ecru -
MH-03 Mono Heathered Grey -
MH-04 Mono Heathered Dark Grey -
MH-05 Mono Heathered Taupe -
MH-06 Mono Heathered Ocher -
MH-07 Mono Heathered Red -
MH-08 Mono Heathered Moss Green -
MH-09 Mono Heathered Pistachio -
MH-10 Mono Heathered Ocean Blue
Mono Eco
Colour and surface options for the Mono Eco range.
4 colours-
ME-01 Mono Eco Chalk White -
ME-02 Mono Eco Light Grey -
ME-03 Mono Eco Grey -
ME-04 Mono Eco Dark Grey
Feltline Flat
Smooth surface, intensely pigmented collection. The widest colour range is here.
45 colours-
FF-01 Feltline Yellow -
FF-02 Feltline Burgundy -
FF-03 Feltline Midnight -
FF-04 Feltline Leaf -
FF-05 Feltline Pink -
FF-06 Feltline Mint -
FF-07 Feltline Apricot -
FF-08 Feltline Orange -
FF-09 Feltline Red -
FF-10 Feltline Azure -
FF-11 Feltline Black -
FF-12 Feltline Cobalt Blue -
FF-13 Feltline Sky Blue -
FF-14 Feltline Coral -
FF-15 Feltline Sea Blue -
FF-16 Feltline Chalk White -
FF-17 Feltline Camel -
FF-18 Feltline Grey -
FF-19 Feltline Brown -
FF-20 Feltline Rust -
FF-21 Feltline Juniper -
FF-22 Feltline Linen -
FF-23 Feltline Taupe -
FF-24 Feltline Sienna -
FF-25 Feltline Forest -
FF-26 Feltline Ruby -
FF-27 Feltline Merlot -
FF-28 Feltline Marine Blue -
FF-29 Feltline Indigo -
FF-30 Feltline Amber -
FF-31 Feltline Onyx -
FF-32 Feltline Paprika -
FF-33 Feltline Pistachio -
FF-34 Feltline Hazel -
FF-35 Feltline Olive -
FF-36 Feltline Ivory -
FF-37 Feltline Terracotta -
FF-38 Feltline Sand -
FF-39 Feltline Periwinkle -
FF-40 Feltline Cornflower -
FF-41 Feltline Powder Blue -
FF-42 Feltline Eucalyptus -
FF-43 Feltline Slate -
FF-44 Feltline Sage -
FF-45 Feltline Moss
Feltline Heathered
Melange textured surface; It gives depth with the mixture of two tones.
45 colours-
FH-01 Feltline Light Green -
FH-02 Feltline Scarlet -
FH-03 Feltline Midnight -
FH-04 Feltline Fern -
FH-05 Feltline Pink -
FH-06 Feltline Mint -
FH-07 Feltline Toffee -
FH-08 Feltline Orange -
FH-09 Feltline Crimson -
FH-10 Feltline Azure -
FH-11 Feltline Charcoal -
FH-12 Feltline Cobalt Blue -
FH-13 Feltline Mauve -
FH-14 Feltline Terracotta -
FH-15 Feltline Sea Blue -
FH-16 Feltline Stone -
FH-17 Feltline Walnut -
FH-18 Feltline Smoke -
FH-19 Feltline Chestnut -
FH-20 Feltline Cinnamon -
FH-21 Feltline Graphite -
FH-22 Feltline Grey -
FH-23 Feltline Flint -
FH-24 Feltline Rosewood -
FH-25 Feltline Oil -
FH-26 Feltline Brick -
FH-27 Feltline Burgundy -
FH-28 Feltline Sapphire -
FH-29 Feltline Ultramarine -
FH-30 Feltline Bronze -
FH-31 Feltline Obsidian -
FH-32 Feltline Cognac -
FH-33 Feltline Celadon -
FH-34 Feltline Mushroom -
FH-35 Feltline Pine -
FH-36 Feltline Pewter -
FH-37 Feltline Mocha -
FH-38 Feltline Clay -
FH-39 Feltline Dusk -
FH-40 Feltline Steel -
FH-41 Feltline Glacier -
FH-42 Feltline Spruce -
FH-43 Feltline Storm -
FH-44 Feltline Lichen -
FH-45 Feltline Basalt
Screen colours may appear different from the actual felt tone. Verify the project colour decision with the current colour chart code.
What to Measure in Conference Acoustics
Speech intelligibility, reverberation time and coverage area of the sound system are evaluated together.
The material report shows the laboratory behavior of the product; The salon result is calculated together with the application area and layout.
As the living room volume increases, the effect of the ceiling and rear wall increases; Intervention zones should be determined by measurement and simulation.
- RT60
- Echo time
- STI
- Speech intelligibility
- Volume
- Hall geometry
- Settlement
- Wall and ceiling distribution
From Project to Installation
-
01First Meeting
Share photographs or plans, or call us to discuss the project scope and design brief.
-
02Project Planning
The product model, thickness, dimensions and mounting details are defined using the architectural drawing. Approved information is transferred to the production package.
-
03Production
Manufacturing begins after approval of colours, dimensions and production drawings. The quotation sets out the delivery schedule for the agreed quantities and project requirements.
-
04Installation
The installation method and site programme are coordinated with the substrate, product system and overall project schedule. Phased installation can be considered where required.
Frequently Asked Questions
Where should the acoustic panel be placed in the conference hall?
Application area; The volume of the hall, its surfaces, seating arrangement and usage style are evaluated together. The scope of wall and ceiling solutions is planned separately for each project.
What is the NRC value, how much should it be for a conference hall?
NRC summarises the product’s sound absorption. Panel selection for a conference hall considers room volume, seating, surfaces and intended use.
What is the difference between sound insulation and sound absorption?
Sound insulation aims to prevent sound from passing from one space to another; This requires heavy and dense materials. Sound absorption reduces echo and noise accumulation in the room. Felt panels are absorbent. The two approaches should be considered together in areas such as meeting rooms.
How does pricing work?
Price; It varies depending on the scope of the project, the selected product model, thickness and amount of m². Since each project is unique, we need to evaluate the project together before giving an exact figure. You can call us or leave a message.
Are the panels suitable for fire safety?
9 mm black PET felt is classified EN 13501-1 B-s1,d0; 9 mm grey PET felt is classified ASTM E84 Class A. Relevant technical documents are available for your project file.
How to clean the panels?
Wipe with a slightly moistened soft cloth. For stains, follow the product's care guide; Do not use excessive water or abrasive cleaners.
Planning Another Venue?
Let's Talk Together for Your Living Room
Share your living room plan or photos; Let our team evaluate the ceiling and wall setup along with measurements.