Acoustic Felt Panels

PET felt acoustic panels reduce sound reflections on walls and ceilings.

A choice of forms, thicknesses and colours brings acoustic treatment into the architectural design.

How Does Felt Panel Absorb Sound?

Hard surfaces such as concrete, glass and painted walls reflect a substantial part of incident sound. Frictional losses as air moves through porous felt convert some sound energy into heat. Absorption varies with frequency and product construction.

24 mm PET felt achieves an NRC sound absorption rating of 0.90. Ratings for the available thicknesses and mounting arrangements are listed in the Technical Data table.

Sound Absorption is Not the Same as Sound Insulation

Sound absorption controls reflections and reverberation within a room. Sound insulation limits transmission between spaces through walls, floors, doors and junctions. PET felt panels are used for sound absorption.

Where Can It Be Used?

Felt panels are particularly useful in spaces with extensive hard surfaces and several people speaking at once.

Where Can It Be Used?
MekânAcoustic Requirements
Open OfficeTalking distance between desks, phone calls and focus areas.
Meeting RoomClear sound in video conferencing; table top canopy and wall panels.
Restaurant and CafeReducing the noise that accumulates in a full hall.
Conference HallConsider the stage, audience layout and reflecting surfaces together.
Educational BuildingsSelect wall and ceiling treatments for speech in classrooms and lecture halls.

Felt Panel Types

There are four main families according to the surface on which it will be applied. Within each family, size, form and colour are selected according to the project.

Five Questions to Choose the Right Panel

  1. 01 Which surfaces are available?

    The ceiling is the largest free surface in most spaces and provides air gap with suspension. If the ceiling is full or very low, the wall and screen stand out.

  2. 02 Which thickness?

    Options include 9, 12, 18, 20 and 24 mm. Thickness is selected to suit the model geometry, fixing detail and acoustic requirements of the project.

  3. 03 How will it be installed?

    Depending on the product, installation uses adhesive, mechanical fixings, rails or suspension. Specify the fixing method, supporting surface and air gap in the installation drawing.

  4. 04 Which colour?

    117 colours; A tone suitable for the corporate identity can be selected with single colour, melange and two-colour lamination options.

  5. 05 What are the fire requirements?

    Products and mounting options are selected according to the reaction-to-fire class required by the project. Relevant technical documents are included in the project package.

PET Felt Technical Values

PET Felt Technical Data
PropertyValue
Composition100% polyester PET felt · 60% recycled content
Thickness and Weight9 mm (±0,5 mm) · 1.600 g/m² (±10%) 12 mm (±0,5 mm) · 2.400 g/m² (±10%) 18 mm · 3.500 g/m² 20 mm (±1 mm) · 3.000 g/m² (±10%) 24 mm (±0,5 mm) · 3.700 g/m² (±10%)
LaminationDual colour · 9 mm (±0.5 mm): 1,600 + 200 + 200 g/m² (±10%) Dual colour · 12 mm (±0.5 mm): 2,400 + 200 + 200 g/m² (±10%) Different colours can be specified for the front and back faces or individual layers.
Acoustic12 mm · 2,400 g/m² · no air gap: NRC 0.45 / αw 0.30 12 mm · 2,400 g/m² · 200 mm air gap: NRC 0.85 / αw 0.75 18 mm · 3,500 g/m² · 200 mm air gap: NRC 0.85 / αw 0.80 24 mm · 3,700 g/m² · 200 mm air gap: NRC 0.90 / αw 0.80 Measured in a laboratory to ISO 354 at the stated thickness and mounting conditions.
Fire TestsEN 13501-1 / B-s1,d0 · AK 1100 black, 9 mm, 1,100 g/m²; mechanically fixed specimen with no air gap ASTM E84 / Class A · Grey Arketa specimen, 9 mm, 177.7 kg/m³ (FTST241350)
Material TestsThe OEKO-TEX certificate and its scope are available on request.
CleaningClean gently with a soft, damp cloth.

Frequently Asked Questions

Does acoustic felt panel provide sound insulation?

No. Felt panel reduces echo inside the room; It does not block the sound passing to the other side of the wall. Sound insulation is provided by the mass and sealing of the building element.

How many panels are required?

Panel quantities are determined by room volume, surfaces and layout. Models, dimensions and mounting options are developed using plans and sections.

Does PET felt burn?

9 mm black PET felt is classified EN 13501-1 B-s1,d0; 9 mm grey PET felt is classified ASTM E84 Class A. Technical documents are available for your project file.

How to clean felt panel?

Gently wipe with a soft, damp cloth. Hard brushes and chemicals containing solvents should not be used; details on the Installation and Maintenance page.

Is PET felt recycled material?

Yes. The PET felt we use is 100% polyester and contains 60% recycled content.

How does the price vary?

Thickness, total area, cutting and form complexity, number of colours, quantity and installation scope determine the price. Quotations are prepared using the project information.

Related Pages