Material

The PET felt used in our panels is 100% polyester and contains 60% recycled content.

Thickness and Mass per Unit Area

Thickness Options and Mass per Unit Area
ThicknessArea weightTolerance
9 mm1,600 g/m²Thickness ±0.5 mm weight ±10%
12 mm2,400 g/m²Thickness ±0.5 mm weight ±10%
18 mm3,500 g/m²—
20 mm3,000 g/m²Thickness ±1 mm weight ±10%
24 mm3,700 g/m²Thickness ±0.5 mm weight ±10%

Two-colour lamination is specified as 1,600 + 200 + 200 g/m² for 9 mm and 2,400 + 200 + 200 g/m² for 12 mm (±10%). Different colours can be used on the front and back faces or in separate layers.

Acoustic Absorption (ISO 354)

Our PET felt options achieve NRC 0.90 sound absorption at 24 mm thickness. Compare thickness and mounting options in the table below.

NRC sound absorption ratings
12 mmno air gap 0,45
12 mm200 mm air gap 0,85
18 mm200 mm air gap 0,85
24 mm200 mm air gap 0,90
ISO 354 test configurations and results
ThicknessArea weightAir gapNRCαw
12 mm2,400 g/m²No air gap0,450,30
12 mm2,400 g/m²200 mm0,850,75
18 mm3,500 g/m²200 mm0,850,80
24 mm3,700 g/m²200 mm0,900,80

Values were measured in a laboratory to ISO 354 using the thickness, mass per unit area and mounting conditions stated in the table.

Panel area and layout are planned around room volume and use.

Fire Tests

Fire test results and test samples
StandardConclusionTest sample
EN 13501-1B-s1,d0AK 1100 black, 9 mm, 1,100 g/m²; mechanical fixation, test specimen without air gap
ASTM E84Class AGrey Arketa sample, 9 mm, 177.7 kg/m³ (FTST241350)

Classifications apply to the specimen and mounting conditions stated in the table.

Material Tests

The OEKO-TEX certificate and its scope are available on request.

How to Read the Results

  • Specify the product code, thickness, mass per unit area and surface finish in the technical file.
  • Show the air gap behind the panel in the mounting section.
  • NRC and αw are different ratings. Check which rating the project specification requires.
  • Read the reaction-to-fire classification with the specimen colour, facing and mounting conditions.
  • Test reports and the product data sheet are provided with the project file.

Plan Your Project

Share plans, sections or photographs so we can discuss suitable products, thicknesses and layouts.