Why Does Acoustic Arrangement in Lecture Halls Determine the Quality of Education?
Sound-absorbing PET felt wall and ceiling systems are manufactured for classrooms and lecture theatres. Products are selected according to room geometry and the acoustic project requirements.
In large-volume lecture halls with hundreds of students, the sound bounces off the back walls, causing the conversation to become blurred and the student to become disconnected from the lesson.
Speech intelligibility is evaluated with criteria such as STI, reverberation time RT60 and background noise. Targets are determined according to the volume of the amplifier and the project standard to which it adheres.
V-Cut panels, flat surfaces and ceiling systems; It is constructed together according to the first reflection points and usage scenario.
Academic Prestige and Uninterrupted Focus
Colours, forms and mounting details of PET felt systems are defined to suit the university’s architectural project. Relevant technical documents are supplied with the product information.
Models, dimensions and mounting options are defined to suit the geometry and use of the space.
Amphitheatre Acoustics Planning: What is Needed in Which Area?
The ceiling structure, podium position and seating arrangement of the lecture hall create different acoustic dynamics. An incorrectly calculated product placement will not solve the problem.
- 01
Rear Wall
The rear wall may create delayed reflections. The required surface application is determined based on the hall geometry and acoustic project. Repetitive reflections occurring between opposing hard surfaces are also evaluated.
- 02
Side Walls
Assess side-wall reflections with the hall geometry and seating layout. Position absorbing or reflecting surfaces while preserving useful sound from speaker to listener.
- 03
Ceiling
Ceiling surfaces are arranged by considering the useful reflections reaching the audience areas and the reverberation that needs to be controlled. The use of baffle or canopy is determined according to the acoustic project of the hall.
- 04
Entrance and Door Surroundings
For the sound coming from the corridor, the sound insulation of the door leaf, casing, wicks and connections is evaluated. Absorbent surfaces around the door can also be considered for in-room reflection control.
Amphitheatre Acoustic Products: Wall Panels
Walls, which make up the majority of the surface area, form the basis of the acoustic project. Model, thickness and application area; It is selected by evaluating the acoustic targets of the space and the frequency-dependent absorption data of the product.
Ceiling Systems
Assess the ceiling, stage and rear wall together in a lecture hall. Preserve useful early reflections while controlling late reflections and excessive reverberation; determine the layout from the acoustic design data.
Technical Specifications
Acoustic, fire and chemical test results of PET felt products are evaluated on a sample basis. After selecting the thickness, colour/series and assembly condition, the relevant report scope is matched in the project file.
- Composition
- 100% polyester PET felt · 60% recycled content
- Thickness and Weight
-
- 9 mm (±0.5 mm) · 1,600 g/m² (±10%)
- 12 mm (±0.5 mm) · 2,400 g/m² (±10%)
- 18 mm · 3.500 g/m²
- 20 mm (±1 mm) · 3,000 g/m² (±10%)
- 24 mm (±0.5 mm) · 3,700 g/m² (±10%)
- Lamination
-
- Dual colour · 9 mm (±0.5 mm): 1.600 + 200 + 200 g/m² (±10%)
- Dual colour · 12 mm (±0.5 mm): 2.400 + 200 + 200 g/m² (±10%)
- Different colours can be used on the front and back surfaces or layers.
- Acoustic
-
- 12 mm 2,400 g/m² without air gap: NRC 0.45 / αw 0.30
- 12 mm 2,400 g/m² 200 mm air gap: NRC 0.85 / αw 0.75
- 18 mm 3,500 g/m² 200 mm air gap: NRC 0.85 / αw 0.80
- 24 mm 3,700 g/m² 200 mm air gap: NRC 0.90 / αw 0.80
- Fire Tests
-
- EN 13501-1 / B-s1,d0 · AK 1100 black, 9 mm, 1,100 g/m²; mechanical fixation, test specimen without air gap
- ASTM E84 / Class A · Grey Arketa sample, 9 mm, 177.7 kg/m³ (FTST241350)
- Material Tests
-
- The OEKO-TEX certificate and its scope are available on request.
- Cleaning
- Clean gently with a soft, damp cloth.
Colour Chart
In the colour chart, there is a 117 option in the 5 series. Check the body and surface options on your product's colour chart.
Mono
Single layer, solid solid colour throughout the panel.
13 colours-
M-01 Mono White -
M-02 Mono Light Grey -
M-03 Mono Grey -
M-04 Mono Dark Grey -
M-05 Mono Black -
M-06 Mono Camel -
M-07 Mono Caramel -
M-08 Mono Orange -
M-09 Mono Red -
M-10 Mono Pine Green -
M-11 Mono Ocean Blue -
M-12 Mono Ash Grey -
M-13 Mono Olive
Mono Heathered
A marled finish version of Mono.
10 colours-
MH-01 Mono Heathered Light Grey -
MH-02 Mono Heathered Ecru -
MH-03 Mono Heathered Grey -
MH-04 Mono Heathered Dark Grey -
MH-05 Mono Heathered Taupe -
MH-06 Mono Heathered Ocher -
MH-07 Mono Heathered Red -
MH-08 Mono Heathered Moss Green -
MH-09 Mono Heathered Pistachio -
MH-10 Mono Heathered Ocean Blue
Mono Eco
Colour and surface options for the Mono Eco range.
4 colours-
ME-01 Mono Eco Chalk White -
ME-02 Mono Eco Light Grey -
ME-03 Mono Eco Grey -
ME-04 Mono Eco Dark Grey
Feltline Flat
Smooth surface, intensely pigmented collection. The widest colour range is here.
45 colours-
FF-01 Feltline Yellow -
FF-02 Feltline Burgundy -
FF-03 Feltline Midnight -
FF-04 Feltline Leaf -
FF-05 Feltline Pink -
FF-06 Feltline Mint -
FF-07 Feltline Apricot -
FF-08 Feltline Orange -
FF-09 Feltline Red -
FF-10 Feltline Azure -
FF-11 Feltline Black -
FF-12 Feltline Cobalt Blue -
FF-13 Feltline Sky Blue -
FF-14 Feltline Coral -
FF-15 Feltline Sea Blue -
FF-16 Feltline Chalk White -
FF-17 Feltline Camel -
FF-18 Feltline Grey -
FF-19 Feltline Brown -
FF-20 Feltline Rust -
FF-21 Feltline Juniper -
FF-22 Feltline Linen -
FF-23 Feltline Taupe -
FF-24 Feltline Sienna -
FF-25 Feltline Forest -
FF-26 Feltline Ruby -
FF-27 Feltline Merlot -
FF-28 Feltline Marine Blue -
FF-29 Feltline Indigo -
FF-30 Feltline Amber -
FF-31 Feltline Onyx -
FF-32 Feltline Paprika -
FF-33 Feltline Pistachio -
FF-34 Feltline Hazel -
FF-35 Feltline Olive -
FF-36 Feltline Ivory -
FF-37 Feltline Terracotta -
FF-38 Feltline Sand -
FF-39 Feltline Periwinkle -
FF-40 Feltline Cornflower -
FF-41 Feltline Powder Blue -
FF-42 Feltline Eucalyptus -
FF-43 Feltline Slate -
FF-44 Feltline Sage -
FF-45 Feltline Moss
Feltline Heathered
Melange textured surface; It gives depth with the mixture of two tones.
45 colours-
FH-01 Feltline Light Green -
FH-02 Feltline Scarlet -
FH-03 Feltline Midnight -
FH-04 Feltline Fern -
FH-05 Feltline Pink -
FH-06 Feltline Mint -
FH-07 Feltline Toffee -
FH-08 Feltline Orange -
FH-09 Feltline Crimson -
FH-10 Feltline Azure -
FH-11 Feltline Charcoal -
FH-12 Feltline Cobalt Blue -
FH-13 Feltline Mauve -
FH-14 Feltline Terracotta -
FH-15 Feltline Sea Blue -
FH-16 Feltline Stone -
FH-17 Feltline Walnut -
FH-18 Feltline Smoke -
FH-19 Feltline Chestnut -
FH-20 Feltline Cinnamon -
FH-21 Feltline Graphite -
FH-22 Feltline Grey -
FH-23 Feltline Flint -
FH-24 Feltline Rosewood -
FH-25 Feltline Oil -
FH-26 Feltline Brick -
FH-27 Feltline Burgundy -
FH-28 Feltline Sapphire -
FH-29 Feltline Ultramarine -
FH-30 Feltline Bronze -
FH-31 Feltline Obsidian -
FH-32 Feltline Cognac -
FH-33 Feltline Celadon -
FH-34 Feltline Mushroom -
FH-35 Feltline Pine -
FH-36 Feltline Pewter -
FH-37 Feltline Mocha -
FH-38 Feltline Clay -
FH-39 Feltline Dusk -
FH-40 Feltline Steel -
FH-41 Feltline Glacier -
FH-42 Feltline Spruce -
FH-43 Feltline Storm -
FH-44 Feltline Lichen -
FH-45 Feltline Basalt
Screen colours may appear different from the actual felt tone. Verify the project colour decision with the current colour chart code.
Things to Measure in Amplifier Acoustics
The student's ability to distinguish speech depends not only on the loudness of the voice, but also on the way it is reflected and the background noise.
Measures such as STI and RT60 are read together; Targets are determined according to hall volume, usage and project standard.
Coverage area, first reflection points and sound system placement determine the result as much as the product selection.
- STI
- Speech intelligibility
- RT60
- Echo time
- dB(A)
- Background level
- Surface
- First reflection points
From Project to Installation
-
01First Meeting
Share photographs or plans, or call us to discuss the project scope and design brief.
-
02Project Planning
The product model, thickness, dimensions and mounting details are defined using the architectural drawing. Approved information is transferred to the production package.
-
03Production
Manufacturing begins after approval of colours, dimensions and production drawings. The quotation sets out the delivery schedule for the agreed quantities and project requirements.
-
04Installation
The installation method and site programme are coordinated with the substrate, product system and overall project schedule. Phased installation can be considered where required.
Frequently Asked Questions
Where should the acoustic panel be placed in amphitheatres?
Application area; The volume, surfaces, seating arrangement and usage style of the amphitheater are evaluated together. The scope of wall and ceiling solutions is planned separately for each project.
What is the NRC value, how much should it be for amplifiers?
NRC summarises the material’s sound absorption. Panel area and layout in a lecture hall follow its geometry, speaker position and seating arrangement.
What is the difference between sound insulation and sound absorption?
Sound insulation aims to prevent sound from passing from one space to another; This requires heavy and dense materials. Sound absorption reduces echo and noise accumulation in the room. Felt panels are absorbent. The two approaches should be considered together in areas such as meeting rooms.
How does pricing work?
Price; It varies depending on the scope of the project, the selected product model, thickness and amount of m². Since each project is unique, we need to evaluate the project together before giving an exact figure. You can call us or leave a message.
Are the panels suitable for fire safety?
9 mm black PET felt is classified EN 13501-1 B-s1,d0; 9 mm grey PET felt is classified ASTM E84 Class A. Relevant technical documents are available for your project file.
How to clean the panels?
Remove surface dust with a soft cloth. For stain and damp cleaning, follow the care guide of the relevant product.
Planning Another Venue?
Let's Talk Together for Your Campus
Share your amplifier plan or photos; Let our team evaluate the appropriate solution and estimated cost with you.