All articles

Open Office Acoustics: Absorption, Zoning, and Speech Propagation

In an open office, a single product does not solve all problems. Ceiling, wall, table space and placement decisions; focus, team communication and circulation zones should be considered together.

Wavy felt ceiling arrangement above work desks in open office

The Real Problem Isn't Noise, It's Apparently Speech

Most of the time, what distracts attention in an open office is not the voice itself, but the ability to distinguish the words. If you can understand a phone conversation three desks away, your brain starts to follow it and gets distracted from your own work. So good open office acoustics doesn't mean silence; It means that speech fades out quickly with distance and the room is not filled with echo.

Wavy felt baffle ceiling in open office
The ceiling is the largest surface in an open office.

Hard surfaces make this difficult. Glass, concrete ceilings, hard floors and empty walls do not absorb sound, they reflect it back. Each reflection carries the conversation a little further and raises the overall sound level in the room. As the level rises, everyone speaks a little louder; The office amplifies its own noise.

Three Separate Jobs: Absorb, Insulate, Block

Three different tasks are often confused when talking about acoustics. Before choosing a product, it is necessary to name which one is needed.

Absorption

The surface does not reflect back some of the sound coming on it. PET felt panels do the job; reduces echo and the overall sound level in the room.

Insulation

Sound insulation limits transmission between spaces through walls, doors, glazing and junction details.

Blocking

The direct path between the speaker and the listener is cut off. Table breaks, screens and hanging dividers are useful for this purpose.

In an open office, absorption and blocking are often needed. In a closed meeting room, insulation comes to the fore. Naming the need correctly is half of choosing the right product.

It Makes Sense to Start from the Ceiling

Table and equipment layout changes over time, while the ceiling remains in place. Felt elements such as baffles and canopies suspended from the ceiling reduce the reflected sound at ceiling height and reduce the overall echo of the volume. This is the first intervention area in most open office projects.

Felt canopy hanging above meeting area
Felt panels hanging from the ceiling in the meeting area.

Since baffles are hung vertically, both sides absorb sound. Canopy, on the other hand, is hung over selected areas, such as meeting tables or seating groups, like a horizontal cloud. The spacing, hanging elevation and occupied area are determined by the geometry of the office. Ceiling; It is full of lighting, ventilation and sprinkler lines, so the layout should be read with these systems on the drawing first.

Click to see the products
BaffleClick to see the productsCanopyClick to see the products

What to Do Between the Table and the Wall?

Ceiling reduces echo; but it does not by itself reduce direct conversation between two people sitting next to each other. For this, it is necessary to place a surface in the sound path. Hanging dividers create a boundary between work groups that both absorbs sound and divides eye contact. This is often what increases the feeling of focus.

Hanging felt screen separating work areas in an open office
suspended acoustic screen: acoustic and visual boundary between work groups.
Wavy felt wall panel in reception area
Felt wall panel: used at selected reflection points.

Hard reflection points are sought on the walls. Glass partitions and empty concrete surfaces carry the conversation to the other side. Plain, V-Cut or printed felt panels applied to selected areas reduce these reflections. It is not necessary to cover every wall of the office; The important thing is to determine which surfaces create the first reflection.

Acoustic wall solutionsClick to go to the pageSuspended Acoustic ScreensClick to see the products

What Do NRC and Air Gap Mean?

You will encounter sound absorption values ​​on the product pages. These values ​​are measured in the laboratory with a standard such as ISO 354, at a specific sample thickness and with a specific mounting clearance. The same felt gives different results when mounted attached to the wall and when mounted away from the wall; The air gap increases absorption. Therefore, a report only makes sense when read together with the sample, thickness and installation condition.

Office layout, treatment area and acoustic targets are planned together.

Result in finished office; It varies depending on the layout, the area covered, the furniture and the use of the office. Quantities specific to the open office, such as how quickly conversation fades with distance, are evaluated by field measurements such as ISO 3382-3. Goals are determined in the project specifications or in the report of the acoustic consultant on the project.

Light and Acoustics in the Same Ceiling

Seating area with felt body acoustic lighting fixtures
Acoustic lighting combines the light source and sound-absorbing felt surface in the same product.

If the ceiling is already crowded with lighting, ventilation and sprinklers, products that combine the light source and felt body can be considered. Hanger and electrical connection according to the details of the model; Light distribution and colour temperature are selected according to lighting requirements.

Click to see the products

Short Checklist for Open Office

Listen to the problem
If the ringing gets longer when you clap your hands, there is an echo. If you can hear the conversation at the neighboring table word for word, the audio path is open.
Get the ceiling plan
Plumbing, lighting and sprinklers should be marked on the drawing; The product placement comes out after that.
First the ceiling, then the immediate surroundings
Baffle and canopy reduce echo; screen and wall panels organize the immediate environment.
Read the report with the condition
Compare sound absorption ratings alongside thickness and mounting information.
Listen again after installation
When the office is occupied, the intelligibility of speech should be re-evaluated.

Table Plan is an Acoustic Plan

In open-plan offices, sources of speech, desk orientation and circulation routes are considered on the same plan. The work area where sound originates and the distance over which it is heard inform the panel layout.

suspended acoustic screens may draw a border in the near field, but the vocal pathways remain open at the top and sides. For confidential conversations, a separate volume defined by a glass partition, door and sealing is required. You don't have to apply a single assembly diagram to all areas of the open plan.

What to Look for After Application?

Speech propagation

If discomfort in focal points persists, re-examine where the speech is coming from and how it changes with distance.

Background sound

If there is plumbing hum, adding more panels without solving the source may not be enough.

Assembly match

Compare the suspension, air gap and module spacing in the product report with the field drawing.

Start with Three Work Zones

Places where phone and video calls take place, places where short team conversations take place, and desks where uninterrupted work is expected do not produce the same behavior. Review the plan based on the intensity of these three uses. Instead of delineating area boundaries only with carpets and furniture, take note of where people talk, where they walk, and who they sit close to.

In an open office, the ceiling can offer space to distribute modules into work zones. However, the relationship of glass facades, partitions and empty walls with table groups should be drawn separately. Wall panels or near-desk dividers are only added to the layout if they serve designated sound paths. Check the decision based on plan, section and intensity of use.

Write the Success Criteria in advance

While echo decreases in one area, speech can still be heard clearly at distant tables. Don't leave success solely to the "the room is quieter" impression. Set individual goals for the project, such as speech propagation, background noise, disturbance in focus areas, and meeting room privacy. Which measurement is required depends on the project and budget.

For a modular open-plan office, removal, transport and rehanging details are resolved during design. Panel layouts are updated alongside desk groups and circulation routes.

Related Products

V-Cut PanelsClick to see the products

Articles on acoustics, PET felt and space design.