Two Separate Properties of Sound: Frequency and Level
Frequency is the number of vibrations per second and is expressed in Hertz (Hz). A low-frequency vent hum and the high-frequency components of speech are different in this regard. The absorption of a material is not equal at all frequencies. Therefore, the results curve by bands in the product report tells more than a single summary value.
Sound pressure level is given in decibels (dB). The decibel scale is logarithmic: we do not read the values of two sources as if they were a plain arithmetic sum. Frequency tells us in which region the sound is located, and level tells us its magnitude at the measurement point. Two sounds of the same frequency can have different levels. When sharing a measurement, location, time, room occupancy and frequency weight used should also be specified.
First, concretize the question in the design: Is the problem the sound remaining in the room after the conversation is over, people speaking at the same time drowning each other out, or the sound coming from the next room? These three situations may require different solutions.
Where Does Sound Go When It Reaches a Surface?
Some sound energy is reflected, some is absorbed in the material and some passes through the surface. Air movement and frictional losses within PET felt’s fibrous structure convert part of the sound energy into heat.
The reflection itself is not always a defect; Early reflections that support the use of space may be helpful. The issue is the time and direction of the reflection. Rapidly repetitive ringing between opposing hard surfaces, delayed returning sound from a large back wall, or concentration of sound at a specific point on a concave surface are treated separately.

Reverberation Time: After the Sound Source Stops
RT60 describes the time corresponding to the 60 dB decrease in the sound level in the room from the moment the source is silent. It is not always possible to obtain a clear range of 60 dB directly in the measurement; In methods such as T20 and T30, shorter decay sections are evaluated and the time corresponding to 60 dB is estimated. The 20 and 30 in their names do not mean seconds.
A long fadeout can carry the energy of one syllable onto the next syllable, making speech difficult to understand. However, there is not the same ideal duration for every room: volume, intended use, occupancy and frequency vary. It is not right to design the conference room and the small meeting room only for the RT60 target. RT60 alone doesn't explain the entire audio experience either; Background noise, speech propagation, and voice privacy can also be examined.
Don't Confuse Absorption with Sound Insulation
Wall or ceiling panel is used to reduce returning sound within the room. Reducing the speech coming from the next room is the subject of the entire building system, which includes partitions, doors, glass, joints and sealing. A hanging divider in an open office can change reflections and line of sight in the immediate environment; It does not behave like a closed and insulated room.
For example, the ringing of your own voice in the meeting room and the sound coming from the corridor may create similar complaints. In the first one, the amount and placement of absorbent surfaces are examined, and in the second one, the door surroundings, glass partitions and indirect transmission paths are examined. Increasing the panel area alone without isolating the problem source may create unnecessary costs.
Location of the Product is as Important as the Product Itself
Baffle and Canopy offer different placement opportunities on the ceiling, while wall panels offer different placement opportunities on vertical surfaces. Which surface to evaluate is determined not only by the amount of free space: show the location of the table, speaker, listener and microphone on the plan; Examine the paths that sound can follow from hard surfaces according to this placement.
In ceiling products, suspension level, module spacing, lighting, air vent, sprinkler and maintenance access are solved in the same section. Wall products include panel joints, sockets, screens and door finishes. Product geometry can establish a decorative rhythm; The acoustic result is evaluated with the actual test data of the product used and the layout calculation.

How Do You Read a Product Report?
Find the product name, thickness and sample description in the first line. Then read the installation: is it fixed directly to the wall, is there an air gap behind it, is it a free-hanging module? Curves of the same material taken with different gaps cannot be treated as the same number. Examine the frequency bands and note the standard and experimental setup under which the report was prepared.
NRC or αw are different odd-numbered indicators used to summarize absorption by frequency; They are not synonymous with each other or with the percentage of in-room sound reduction. RT60 is a feature of a room, not a product. Rw or STC is related to the sound transmission of the building element. Instead of just writing a number in the specification, specify the sample being tested and the assembly layout.
Sample Reading: A Meeting Room with a Glass Front
In a sample room with a glass facade, hard floor and flat ceiling, the table, screen and microphone locations are marked in the first drawing. Whether the most disturbing sound during use is in-room ringing or passing in the corridor is distinguished by observation and, when necessary, measurement.
- Wall
- UNICA Mono or another suitable panel family is considered on the usable wall opposite the glass. The joint layout aligns with the screen, socket and furniture; The area to be covered is determined by calculation.
- Ceiling
- If the wall area is limited, Baffle or Canopy possibility is tried in the section. Conflicts with fixtures, sprinklers and service access are eliminated.
- Door and partition
- If the sound coming from the corridor is obvious, door, glass partition and joint details are a separate work package; The panel added into the room does not block this path.
- Control
- For before-and-after comparisons, record occupancy, furniture, door positions and measurement locations under consistent conditions.
The final submission should include a short project brief, drawings showing product positions and installation levels, and technical documentation matching the selected specimen and mounting conditions. Recheck the document scope if the form or colour changes.